Home Up Products Saving Energy Glossary Contents About / Contact

Magnum MS PAE 120/240V Inverter Specifications

The MS-AE Series is a pure sine wave inverter designed specifically for split phase 120/240V  renewable energy applications.  The MS-AE produce 120/240 volt output in one inverter, eliminating the need to stack two inverters together to obtain 240 volts output and are ETL listed to the stringent requirements of UL 1741 and CSA STD C22.2 No.107.1-01 for renewable energy installations.

No series stacking required! The unique design of the MS-PAE Series can provide 120 and 240 volts output in one unit, eliminating the need to stack two units together to produce 240 volts.

Up to four inverter/chargers can be parallel stacked to produce up to 17.6kw of power at 120/240V.  MP panels and router are required for parallel stacking the MS-PAE Series.

A Power Corrected Factor (PFC) charger is built in and uses less energy from a generator than a standard charger,  using 25-30% less AC current than standard chargers.

The MS-PAE Series is ETL Listed to the stringent requirements of UL 1741, 1st edition, and CSA C22.2 #107.1-01 for renewable energy installations.

MS-PAE Series MS4024PAE MS4448PAE
Inverter Specifications  
Input battery voltage range 18.0 - 34.0 VDC 36.0 - 64.0 VDC
Nominal AC output voltage 120/240 VAC split phase ( 5%)
Output frequency and accuracy 60 Hz 0.1 Hz
Total Harmonic Distortion (THD) < 5%
1 msec surge current (amps AC) Line-Neutral: 120, Line-Line: 70
100 msec surge current (amps AC) Line-Neutral: 72, Line-Line: 40
5 sec surge power (real watts) 5800 8500
30 sec surge power (real watts) 5200 6000
5 min surge power (real watts) 4800 5400
30 min surge power (real watts) 4500 4800
Continuous power output at 25 C 4000 VA (L-L)
Maximum continuous input current 266 A 144 A
Inverter efficiency (peak) 93% 94%
Transfer time 16 msecs
Search mode (typical) < 6 watts
No load (120 VAC output, typical) 27 watts 25 watts
Waveform Pure Sine Wave
Charger Specifications    
Continuous output at 25 C 105 ADC 60 ADC
Charger efficiency 85%
Power factor > 0.95
Input current at rated output (AC amps) 15 AAC per leg 17.5 AAC per leg
  at 120/240 VAC split phase
General Features and Capabilities  
Transfer relay capability 2 legs at 30A per leg transfer standard on all models
Five stage charging capability Bulk, Absorb, Float, Equalize (requires remote), and Battery Saver
Battery temperature compensation Yes, 15 ft Battery Temp Sensor standard
Internal cooling 0 to 120 cfm variable speed drive using dual 92mm brushless DC fans
Overcurrent protection Yes, with two overlapping circuits
Overtemperature protection Yes on transformer, MOSFETS, and battery
Conformal coating on PCBs for corrosion protection Yes
Powder coated chassis & top for corrosion protection Yes
Stainless steel fasteners for corrosion protection Yes
Listings ETL Listed to ANSI / UL1741, 1st edition, and CSA STD C22.2 No.107.1-01
Warranty Three years parts and labor (five years when installed on MMP or MP system)
Environmental Specifications  
Operating temperature -20 C to +60 C (-4 F to 140 F)
Nonoperating temperature -40 C to +70 C (-40 F to 158 F)
Operating humidity 0 to 95% RH non condensing
Physical Specifications  
Dimensions (l x w x h) 13.75 x 12.65 x 8.0 (34.9 cm x 32.1 cm x 20.3 cm)
Mounting Shelf, wall (no vents on bottom), MP or MMP panels
Unit Weight 55 lb (24.9 kg) 55 lb (24.9 kg)
Shipping Weight 62 lb (28.2 kg) 63 lb (28.6 kg)
Max operating altitude 15,000 (4570 m)

Home Up Products Saving Energy Glossary Contents About / Contact

 

Contact Us: Telephone:  toll free at 1-888-810-4709 Parry Sound,Northern Ontario,Muskoka and Georgian Bay
Send mail to:info@stratenergy.ca  with questions or comments about our product or web site.

Ontario,Canada Copyright 2013, STRATEnerGY Inc.    All Rights Reserved Caribbean and US
Last modified: March 01, 2017