Trojan UV Water
Sterilization
Trojan UV has products
that range in size and application from standard household capacities to
equipment that will serve campgrounds, parks and hotels through to civic
projects.
The products described below
are standard configurations. We will put you in touch with application
engineers if your project requirements exceed the processing capacities of those
listed below.
Unless otherwise indicated,
information contained on this page is Copyright © 2006 Trojan Technologies
Trojan UV Water
Sterilization Systems offer the following features:
- unique combination
of the lamp and sleeve - for simple maintenance

- timer notifies of the
need to replace the lamp
- diagnostic display
explaining why the system may be in alarm
- ten-year warranty
against manufacturer’s defects on the UV chamber
- three years warranty
on the circuit boards, power supply, and all electrical connections
- smaller size through
optimized efficiency of fluid dynamics
|
Residential Trojan UV Water Sterilizers |
A |
B4 |
C4 |
D4/D4 Plus |
E4/E4 Plus |
F4/F4 Plus |
|
Application |
faucet |
Faucet or
small cottage |
Average home |
Larger than
average home |
Large home or
commercial application |
|
Flow Rate |
0 – 3 GPM
(0 – 11 LPM) |
3 – 6 GPM
(11 – 23 LPM) |
7 – 16 GPM
(26 – 60 LPM) |
7 – 16 GPM
(26 – 60 LPM) |
12 – 29 GPM
(45 – 110 LPM) |
20 – 45 GPM
(76 – 170 LPM) |
|
Constant current electronic power supply |
yes |
|
Safety cap & special lamp plug |
Safety cap only |
yes |
|
Lamp operation indicator |
yes |
|
Power supply operation indicator |
yes |
|
Sensor operation indicator |
- |
Plus Models |
|
Sensor with diagnostic test |
- |
Plus Model |
|
Lamp timer display |
- |
yes |
|
Mute button |
- |
yes |
|
Water Shutoff Solenoid Valve |
- |
optional |
|
External control relay |
- |
optional |
|
Chamber material |
304 SST |
316 SST |
|
Inlet/outlet |
3/8" FNPT |
3/4" NPT |
1" NPT |
|
Chamber dimensions |
39 x 6.5cm |
37 x 10cm |
52 x 10cm |
76 x 10cm |
112.5 x 10cm |
|
Power supply dimensions |
7 x 8cm |
22 x 15cm |
|
Voltage |
100-240V AC |
|
Frequency |
50-60Hz |
|
Max. current |
0.4Amp |
0.4Amp |
0.5Amp |
0.5Amp |
0.85Amp |
1.2Amp |
|
Max. power consumption |
22 W |
36 W |
50 W |
50 W |
83 W |
130w |
|
Lamp power |
14 W |
25 W |
40 W |
40W |
70 W |
110 W |
|
Maximum operating pressure |
125 PSI (862 kPa) |
|
Maximum ambient air temperature |
122°F (50°C) |
|
Minimum ambient air temperature |
32°F (0°C) |
|
Maximum hardness |
120 ppm (7 grains per gallon) |
|
Maximum iron |
0.3 ppm |
|
Minimum UVT |
75% |
|
Installation |
Vertical or horizontal (Systems with sensors must be installed vertically) |
|
Certifications |
 |
|